ASHRAE and IECC Lighting Control Requirements by State


Lighting Control Code Requirements by State

Arizona:

  • IECC 2012
  • IECC 2018

Arkansas:

  • IECC 2009

Colorado:

  • IECC 2015
  • IECC 2018

Georgia:

  • IECC 2015

Kansas:

  • IECC 2006

Louisiana:

  • ASHREA 90.1 - 2007

Missouri:

  • IECC 2009
  • IECC 2012
  • IECC 2015

New Mexico:

  • IECC 2018

Oklahoma:

  • IECC 2006

Tennessee:

  • IECC 2012

Texas:

  • IECC 2015

IECC Lighting Control Requirements by Year

 = New Construction and Retrofit
Lighting Device IECC
2009 2012 2015
Manual Control
Light Reduction Control
Time-Switch Controls
Occupancy Sensor Control ---
Occupancy Sensor Control:
Restricted to Manual ON
---
Occupancy Sensor Control:
Restricted to Partial Automatic ON
---
Occupancy Sensor Control:
Automatic Full OFF
---
Occupancy Sensor Control:
Occupancy Sensor Timeout
--- 30 min 30 min
Daylight Responsive Control ---
Manual ---
Automatic --- ---
Guest Room Control Manual Manual Automatic
 = New Construction and Retrofit
Lighting Device IECC
2018 2021
Manual Control
Light Reduction Control
Time-Switch Controls
Occupancy Sensor Control
Occupancy Sensor Control:
Restricted to Manual ON
Occupancy Sensor Control:
Restricted to Partial Automatic ON
Occupancy Sensor Control:
Automatic Full OFF
Occupancy Sensor Control:
Occupancy Sensor Timeout
20 min 20 min
Daylight Responsive Control
Manual --- ---
Automatic
Guest Room Control Automatic Automatic

ASHRAE 90.1 Lighting Control Requirements by Year

 = New Construction

 = New Construction and Retrofit

Lighting Device ASHREA 90.1
2007 2010 2013
Local Control
Bilevel or Multilevel Control ---
Scheduled Shutoff
Occupancy Sensor
Occupancy Sensor:
Restricted to Manual ON
--- ---
Occupancy Sensor:
Restricted to Partial Automatic ON
--- ---
Occupancy Sensor:
Automatic Partial OFF
---
Occupancy Sensor:
Automatic Full OFF
Occupancy Sensor:
Occupancy Sensor Timeout
30 min 30 min 20 min
Daylight Responsive Control ---
Receptacle Control ---
Guest Room Control Manual Manual Automatic

 = New Construction

 = New Construction and Retrofit

Lighting Device ASHREA 90.1
2016 2019
Local Control
Bilevel or Multilevel Control
Scheduled Shutoff
Occupancy Sensor
Occupancy Sensor:
Restricted to Manual ON
Occupancy Sensor:
Restricted to Partial Automatic ON
Occupancy Sensor:
Automatic Partial OFF
Occupancy Sensor:
Automatic Full OFF
Occupancy Sensor:
Occupancy Sensor Timeout
20 min 20 min
Daylight Responsive Control
Receptacle Control
Guest Room Control Automatic Automatic

Lighting Products

Lutron Smart Switch for Caseta

Lutron Smart Switch for Caseta smart home

Lutron smart switch work with Caseta smart-home system for customizable automatic lighting.

Shop Smart Dimmers

Occupancy Sensor Switch

occupancy vacancy sensor

Occupancy sensor switches are a cost-saving option that activate when it senses motion.

Shop Occupancy Sensors

Dimmer Switch Control

switch-dimmer-slide-control

Light dimmers adjust and control the brightness of lighting fixtures for customized illumination levels.

Shop All Dimmer Switches

Electric Timer Switch

7 day timer switches

Electric timer switches automate the on/off function on customized time-based schedule.

Shop Timer Switch

Manual Switch

grounding-toggle-switch

Manual switches are simple to use and don't rely on additional technology to operate.

Shop Manual Switches

Dual Circuit Motion Sensor

Dual circuit ultrasonic infrared switch

Dual circuit sensor combines ultrasonic waves and passive infrared for reliable automatic sensing.

Shop Dual Circuit Sensor

Warning: When using this information to perform electrical work, call a licensed electrician or consult the NEC® for safety. All licensed electricians have passed examinations covering the National Electric Code®, know state and local building codes, and may carry insurance to cover damages.